Issue |
J Oral Med Oral Surg
Volume 30, Number 2, 2024
|
|
---|---|---|
Article Number | 15 | |
Number of page(s) | 7 | |
DOI | https://doi.org/10.1051/mbcb/2024018 | |
Published online | 08 August 2024 |
Original Research Article
Evaluation of early marginal bone loss around posterior dental implants placed in axial and non-axial positions: a retrospective cone beam computed tomography (CBCT) analysis
Department of Periodontics and Implantology, Vishnu Dental College, Vishnupur, Bhimavaram 534202, West Godavari, Andhra Pradesh, India
* Correspondence: sruthima@gmail.com
Received:
11
November
2023
Accepted:
20
June
2024
Introduction: To retrospectively assess the mesio-distal angular deviation/inclination of single implants restored in the posterior edentulous arches and evaluate the effect of angular deviations on the early bone loss after 12 months of functional implant loading. Materials and methods: This retrospective Cone beam computed tomography (CBCT) analysis assessed 60 single implants including 36 axially placed (AX Group) and 24 non-axially (NAX Group) placed implants of dimension 4.2 × 10 mm. Marginal bone loss (Mesial, Distal) was assessed at 1 year post implant loading in both maxillary and mandibular implants. Independent sample t-test was done for intergroup comparison and paired t-test for intragroup comparisons. Results: Mean MBL was significantly greater (P-0.02) in NAX group compared to AX group on both mesial and distal sides. Maxillary implants showed greater MBL (3.17 ± 1.33, 2.99 ± 1.63 on mesial and distal sides respectively) compared to mandibular implants (1.86 ± 0.53, 2.29 ± 0.90 on mesial and distal sides respectively). Conclusion: Greater mean MBL during first year of functional loading in NAX group and maxillary implants was observed with minimal post-operative complications and good survival rate in both groups.
Key words: Bone loss / cone beam computed tomography / dental implant loading / dental implant single tooth
© The authors, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.