Open Access
Table II
Main characteristics and results of the included studies. grey cells: missing data; black cells: data not relevant. N°: number; ISQ°: implant stability quotient; SD : standart deviation; ø°: diameter; W°: weeks; M°: months; Y°: year.
Selected study (first author and publication year) | Type of study | Patients (n) | Type of bone | Implants (n, characteristics) | ISQ + SD | Implant failure, remark | Radiation dose |
---|---|---|---|---|---|---|---|
Bafijari (2019) | Prospective | 42 | Native mandible | 77 | D0= 63.81±9.48, M3= 70.25±9.3 |
0 | |
Faot (2019) | Prospective | 31 | Native mandible | 62 Neodent®: ø 2.9-10mm |
12 | ||
García (2011) | Prospective | 70 | Native mandible | 68 MG-Osseous®:ø 3.75-4.25mm | D0=79.6±5.4, D110=77.45±5.6 | 2, decrease of more than 10 ISQ points was observed in RFA between first and second surgical stages. |
|
Gehrke (2014) | Prospective | Native mandible | 41 De Bortoli® ø 3.5-5mm Length 8-13mm |
D0=65.5, M3=72.9, M5=75.3 | 0 | ||
Guirado (2015) | Prospective | 10 | Native mandible | 60 Straumann® Length 4-10 mm |
Shorts: D0=75.22±1.23, M3=78.33±1.76, M6=79.65±0.56, M12=80.20±0.44 Conventional: S0=78.72±2.13, M3=81.67±1.22, M6=82.45±0.78, M12=82.34±0.67 |
1 | |
Guler (2013) | Prospective | Native mandible | 95 Straumann® ø 3.3-4.8mm Length 8-14 mm |
D0= 65.9±8, M1= 64.4±7.6, M2= 72.1±5.5 | 0 | ||
Hadzik (2017) | Prospective | 13 | Native mandible | 16 shorts Astra® (OsseoSpeed TX Bone Level) 16 shorts Straumann® (SLActive, Tissue level) |
Astra® D0=77.8±6.1, M3=78.9±7.8, Straumann® D0=66.5±16.5, M3=73.9±8.4 |
0 | |
Hakobyan (2020) | Prospective | 27 | Fibula graft | 134 | D0 = 65, M3=73 | 7 | 0 Gy |
Karl (2008) | Retrospective | Native mandible | 226 Straumann®: ø 3,3-4,8mm, Length 6-16mm |
Anterior mandible (n=65): D0=71.92±7.8, S7=76.84±4.9 Posterior mandible (n=161): D0=75.98±5.9, S7= 79.45±4 |
0 | ||
Krafft (2015) | Prospective | Native mandible | 264 Straumann®: ø 3.3-4.8mm Length 6-14mm |
D0 = 75.3, W6= 76.96 | <8 | ||
Kramer (2005) | Prospective | 16 | Fibula flap | 51 ø 3.75mm Length: 10-15mm |
D0= 70.1, M3= 71.4, M12=76 | 3 | 0 Gy |
Makary (2012) | Prospective | Native mandible | 40 Zimmer®: ø 4.1-4.7mm |
D0=82, W3=78, W6 =78 | 0 | ||
Mei (2022) | Prospective | Native mandible | 32 Straumann®: ø 4.1-4.8mm |
Osteotome: D0=70.75±4.28, W1=72.39±3.99, W2=72.55±4.62, W3=72.87 +/−2.9, W4=74.05 +/− 2.91, W6=75.77+/−1.97, W8=76.47±2.52, W10 =76.83±2.78, W12=77.5±3.09 Conventional: D0=78.33±6.63, W1=76.74±7.76, W2=74.26±6.34, W3=76.52±6.34, W4=77.09±6.39, W6=77.57±5.32, S8= 78.48±4.77, W10=78.33±4.55, W12=78.68±4.51 |
0 | ||
Möhlhenrich (2016) | Prospective | 25 | Fibula graft | 50 Straumann® | D0=79.48±2.35, W20=75.59±5.11 |
7 patients | |
Morales (2012) | Prospective | 8 | Native mandible | 30 Dentsply® | D0: C(Control) = 75.7 SD 5.6, L (Laser) = 77.4 SD 3.4 D10: C = 76.2±4.6, L = 78.9±3.7 W3: C = 76.9±3.5, L = 76.8±4.6 W6: C= 76.3±2.3, L = 75.5±4.0 W9: C = 77.7±3.5, L = 76.2±4.9 W12: C = 78.4±3.0, L = 76.3±4.1 |
0 | |
Pieri (2012) | Prospective | 25 | Native mandible | 61 | D0=67.35±6.67, Y2=72.91±5.07 | 2 | |
Queiroz (2015) | Prospective | 23 | Native mandible | 48 shorts: ø 5mm Length 5.5-7 mm; 42 regular: ø 4mm Length 10-11.5 mm |
D0: S(short) = 71; C (conventional) = 63, W2 S = 68, C =65, M1 S = 71, C = 70, M2 S = 69, C= 71, M3 S = 70, C = 70 |
Survival rate (90 days) 87.5% for shorts and 100% for regular |
|
Saracoglu (2015) | Prospective | 40 | Native and irradiated mandible | 80 Straumann® | Native: D0= 68.4±9.6, W1= 60.05±6.9, W2=59.05±6.3 M3 (loading)= 67.95±6.6, M4= 62.15±6.1, M6= 70.7±7.3, Y1 = 75.75±6.5 Irradiated: D0= 62.4±7, W1= 52.1±5, W2=49.25±3.3, M3 (loading)=59.65±6.4, M4: 55±3.7, M6 = 63.65±5.7, Y1= 67.3±7.1 |
||
Shokri (2013) | Prospective | 10 | Native mandible | 15 Straumann® | D0= 77.20±4.92, W1=77.00±3.51, W2= 74.20±3.82, W3= 73.20±5.19, W4=72.13±5.69, W5= 72.33±4.62, W7= 73.55±3.89, W11=75.60±3.72 |
0 | |
Sreerama (2021) | Prospective | Native mandible | D0= 69.75, M6 = 69.05, Y1= 71.7 | <15 RFA=65.4±5.8 in successful implants and 45.8±4.1 in failed implants |
|||
Støre (2011) | Prospective | 31 | Irradiated mandible | 125: Astra®,Straumann®, 3i®, Nobel® ø 4.1-4.5mm Length 10-15mm |
16 (8 ORN) | 50-70 Gy | |
Sun (2016) | Prospective | 32 | Native mandible | 45 Straumann®: RN ø 4.8 Length 10 mm |
Smokers: D0=82, W1=76, W2=72, W3=72, W4=74, W6=76, W8=78, W12=80 No smokers: D0=78, W1=76, W2=68, W3=76, W4=78, W6=80, W8=81, W12=82 |
0 | |
Tözüm (2016) | Prospective | 82 | Native mandible | 82 Zimmer®: ø 3.75-4.7mm, Length 8-13 mm |
D0=68±2.5, M12=71.77±2.01 | ||
Velloso (2019) | Prospective | 20 | Native mandible | 20 Néodent®: ø 3.75mm Length 11mm |
Hydrophilic: D0=62.7±8.6, W1=65.1±5.9, W2=64.9±8.3, W3=65.9±6,6, W4=66.3±5.5, W5=66.9±5,8, W6=67.1±5.9 Control: W0=63.5±8.4, W1=62.9±8.9, W2=59.2±8.6, W3=58.5±8.1, W4=59.1±7.7, W5=60.4±7.4, W6=61±7.2 |
0 | |
Waechter (2017) | Prospective | Native mandible | 40 Signo®: 20 tapered: ø 4.60 mm 20 cylindrical: ø 4mm Length 10 mm |
D0: Tapered (67.86±12.28) cylindrical (62.62±16.99) W1: Tapered (53.97±17.86) cylindrical(59.54±14.55) W2: Tapered (69.29±13.55) cylindrical (67.65±15.47) W3: Tapered (77.58±9.59) cylindrical (77.96±8.12) W6: Tapered (71.19±9.67) cylindrical (71.90±12.84) W10: Tapered (73.58±8.58) cylindrical (70.87±7.94) M3: Tapered (78.61±8.85) cylindrical (79.62±8.52) |
3 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.