Summary of scientific data on implant loading guided by Ostell (ISQ).

ISQ value <60 (Low stability) 60–64 (Medium stability) 65–69 (Medium stability) ≥70 (High stability)
  2-stage, conventional loading, re-measure at follow-up > 2 months [11,12]

Consider conservative approach due to low implant stability (i.e., relatively high implant mobility) [13]
Full splint: 1-stage, immediate loading
Partial case: 1-stage, immediate loading
Single case: 2-stage, conventional loading, re-measure at follow-up >2 months [11,12,14]
Full splint: 1-stage, immediate loading
Partial case: 1-stage, immediate loading
Single case: 1-stage, early loading, re-measure at follow-up 6-8 weeks [11,15,16]
Full splint: 1-stage, immediate loading
Partial case: 1-stage, immediate loading
Single case: 1-stage, immediate loading [11,15,17,18]